  Datasheet File OCR Text:
  specification order no. safety model no. dc voltage note.2 rated current current range rated power (max.) ripple & noise (max.) note.3 output voltage range note.9 frequency range power factor (typ.) efficiency (typ.) ac current (typ.) input environment inrush current (max.) leakage current(max.) safety standards safety & emc (note. 7) working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing protection gs90a15-p1m GS90A12-P1M gs90a19-p1m gs90a24-p1m gs90a48-p1m 15v 12v gs90a15 gs90a12 19v gs90a19 24v gs90a24 48v gs90a48 100mvp-p 80mvp-p 150mvp-p 180mvp-p 240mvp-p voltage tolerance note.4 line regulation note.5 load regulation note.6 5.0% 5.0% 4.0% 3.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 5.0% 5.0% 4.0% 3.0% 2.0% 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz pf>0.91 / 230vac pf>0.95 / 115vac at full load 89% 88% 89% 89.5% 91% 2a / 115vac 1a / 230vac 70a / 230vac 1ma / 240vac withstand voltage isolation resistance i/p-o/p: 3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg / 25 / 70% rh :100m ohms / 500vdc 348.7khrs min. mil-hdbk-217f(25 ) -30 ~ +50 (refer to "derating curve") 20% ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03% / (0~50 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 145*60*32mm (l*w*h) 0.45kg; 30pcs/14.05kg/1cuft connector plug cable standard type for stock ther type available by customer requested p1m: 2.5 * 5.5 * 11mm, tuning fork type, center positive ; o see page 2 ther type available by customer requested ; o 1. all parameters are specified at 230vac input, rated load, 25 70% rh ambie nt. 2. dc voltage: the output voltage set at point measure by plug terminal & 50% loa d. 3. ripple & noise are measured at 20mhz by using a 12" twisted pair terminated wi th a 0.1uf & 47uf capacitor. 4. tolerance: includes set up tolerance, line regulation, load regula tion. 5. line regulation is measured from low line to high line at rated load. 6. load regulation is measured from 10% to 100% rated load 7. the power supply is considered as an independent unit, but the final equip ment still need to re-confirm that the whole system complies with the emc directives. 8. length of set up time is measured at first cold start. turning on/off the powe r supply may lead to increase of the set up time. 9. derating may be needed under low input voltages. pleas check the derati ng curve for more details. 90w ac-dc single output desktop g s 9 0 s e r i e s features : compliance to en61000-4-2,3,4,5,6,8,11, light industry level, c riteria a overload over voltage 110 ~ 150% rated output power protection type : hiccup mode, recovers automatically after fault con dition is removed 105 ~ 135% rated output voltage 6a 6.67a 4.74a 3.75a 1.87a 0 ~ 6a 0 ~ 6.67a 0 ~ 4.74a 0 ~ 3.75a 0 ~ 1.87a 90w 80w 90w 90w 90w protection type : shut down o/p voltage, re-power on to recover ul60950-1, tuv en60950-1, bsmi cns14336, approved j60950-1(except for 48v) compliance to en55022 , fcc part 15 / cispr22 class b class b en61000-3-2,3, , cns13438 class b, gb17625.1 universal ac input / full range 3 pole ac inlet iec320-c14 protections: short circuit / overload / over voltage / over temperature fully enclosed plastic case approvals: ul / cul / tuv / bsmi / cb / fcc / ce class power ( with earth pin) pass lps led indicator for power on no load power consumption<0.5w meet eisa 2007(energy independence and security act) 2 years warranty built-in active pfc function, pf>0.91 tuv rheinland product safety geprufresicherheit file name:gs90-spec 2011-06-15 setup, rise time note.8 hold up time (typ.) 1000ms, 20ms / 230vac 1000ms, 20ms / 115vac at full load 20ms / 230vac 20ms / 115vac at full load over temperature rth30 > 100 protection type : shut down o/p voltage, re-power on to recover (except for 48v) emc immunity emc emission
70 10mm 11 0.5mm mechanical specification file name:gs90-spec 2011-06-15 ambient temperature ( ) load (%) 0 -30 20 10 30 40 20 40 50 80 60 100 60 50 70 input voltage (vac) 60hz 90 100 95 120 110 160 140 200 180 240 220 264 load (%) ta=25 90 100 80 70 60 50 40 (horizontal) derating curve static characteristics 145 32 60 power led plug assignment standard plug: p1m id 2.5 x od 5.5 c"+" p/n output p1m center + g s 9 0 s e r i e s 90w ac-dc single output desktop ul1185 14awg 1000 50mm for 12v ~ 15v ul1185 16awg 1200 50mm for 19 ~ 48v case no. 978a unit:mm


▲Up To Search▲   

 
Price & Availability of GS90A12-P1M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X